Continuing with my gap analysis series, in this post I’ll examine what causes a Tampering Risk to occur, and its impact on the business if the risk is not detected and resolved.

Gap: Tampering Risk

Risk: DR failure and data corruption

How does it happen? This hidden risk is the result of an unauthorized host at the DR site erroneously configured with access to one or more storage devices. This is a very common error, and, much to the surprise of many organizations, there are dozens of reasons why it can happen. In each case, however, it can remain dormant during normal operations and is only revealed during an actual full-blown disaster. Here are just a few reasons why this error may occur:

  • When performing a storage migration, the storage administrator forgets to remove old device mappings to the host. After repurposing the old devices to new hosts, some are still visible by the original, now unauthorized host.
  • From time to time, extra mapping may be added to increase performance or resiliency of access to the disk. If zoning and masking are not controlled and managed from a central point, one of the paths might actually go “astray.”
  • Sometimes HBAs are replaced not because they are faulty but because greater bandwidth is required. If soft-zoning is used and is not updated accordingly, an old HBA still retains permission to access the original storage devices. Once the HBA is reused on a different host (which can occur months after the upgrade) this host will actually get access rights to the SAN devices which belong to the original host.

What is the impact? During a disaster, a racing condition, with several unpleasant scenarios, will develop:

  • Scenario 1—The unauthorized host might gain exclusive access to the erroneously mapped disk. In this case, the designated standby will be unable to mount and use the locked devices, and it could take some time to isolate and fix the problem. There is also the risk of the unauthorized host actually using the erroneously mapped disk, thereby corrupting the data and rendering recovery impossible.
  • Scenario 2—Both the standby and the unauthorized hosts get concurrent access to the disk. If the unauthorized host attempts to use the erroneously mapped disk, not only will the data be corrupted instantly, but the now-active standby may unexpectedly crash.

Why does the DR test miss this? Simply put, because all hosts are rarely brought up at the same time. As already explained, many organizations choose to test only one subset of the environment at a time. During a test, both the original and unauthorized server would not be started at the same time, but in a real event they would, and will wreak havoc on the data.